912 Ignition debug procedures
Wondering if anyone cares to help me do the right ignition debug sequence for 912ULS. The ignition debug procedure still gets my head spinning a bit.
Runup 4000 RPM resulted in a “miss”, roughness on the B switch but with only a moderate RPM drop (100-150). Sometimes ran smooth for 10 seconds or so, then missing a bit. Checked all plugs. Looked clean. Plugs have 50 hours on them. Checked all plug connections OK. New plugs on order anyway.
- Ran test with choke/starting carbs full on. No apparent change. B switch still rough, but no better/worse.
- Swapped horizontal connectors. Issue moved to A switch.
- Moved horizontal connectors back and swapped vertical connectors. Issue moved to A switch. (Seems wrong somehow that both 2 and 3 would result in switch?).
- Swapped P leads, issue moved to A switch.
- Pulled one trigger coil wire for A module - B switch/A coil 500RPM drop. A switch OK.
- Pulled other trigger coil wire for A module - B switch/A coil 500RPM drop. A switch OK.
- Swapped Red charging coil wires - Issue moved to A switch
- Checked resistance on Red wires. 3.9-4.1 Ohms.
- Put all back to normal. Issue seemed to temporarily be gone or very intermittent now. Need another test to confirm.
Wondering first if I wrote everything down right. Is it logical for the issue to have moved in the way I described at each step? Then, of course, what specific thing might I implicate?