When testing ignition A & B at 4000 rpm I get a drop on both of 1000 rpm. The same drop on A and on B. Any ideas?
When testing ignition A & B at 4000 rpm I get a drop on both of 1000 rpm. The same drop on A and on B. Any ideas?
by Capt. Siva, » 5 years ago
It may be trigger coil faulty, check trigger coil or Trigger coil gap issue.
trigger coil air gap .020"
Gap greater than .035". It will stop firing or MAG drop. Check it and tell again.
'Stay home and say thank you
by Bill Hertzel » 5 years ago
That much of a drop might indicate you are running on 3 cylinders and the bad A plug is in a different cylinder than the B.
Look at your EGT temps to identify the culprit.
If you do not have EGT's try an IR temp gun, or just start it on one mag at a time for 10 seconds and see which exhaust pipe stays cold.
Bill Hertzel
Rotax 912is
North Ridgeville, OH, USA