Hello all

I am new to the forum.  I did my first start on a 912iS that is installed in a Kitfox S7SS.  Some good news some not so good and I hope someone can help getting it sorted out.

Good news it started, has oil pressure etc. Ran smooth, no leaks of any kind.  Bad news is that it is not charging the battery. My Dynon 5600 was flashing "no amps".  After running it for about 10-15 minutes I checked the battery voltage and it read 12.2 volts so it is definitely not charging.

I'm not sure where to start looking for the problem.  I opened the fuse box but don't see any blown fuses.  Which brings up another question.  Where do I find out what each fuse is for?  I'm certain that everything is connected properly.

Any information would be appreciated.

Joe

  • Re: 912iS not charging

    by » 4 years ago


    First question. Did you run it up to 2500 rpm for up to 5 seconds to allow the 2nd generator to come on line?


  • Re: 912iS not charging

    by » 4 years ago


    In order to properly diagnose this, you would need to extract the ECU data! 

    Since it is a Kitfox, have you talked to John Mcbean in regards to this issue?

    The fuse description is in the Rotax Maintenance manual that you can lookup by clicking on this link here - https://www.rotax-owner.com/en/support-topmenu/engine-manuals#912-i-series-engines

    It can be found in section 76-10-00 Page 39

    https://www.rotax-owner.com/manuals/MMH_912i_Series_ED1_R3.pdf

    From the Rotax 912iS maintenance manual

    The internal generator has two isolated coils integrated (individual generators). During the starting operation, the EMS system is powered by the battery. With sufficient speed generator B takes over this function. After the EMS system check, generator A takes over the supply of the EMS system (engine), if the switching threshold is exceeded. Generator B is then used to supply the aircraft instruments and for charging the battery. While the engine is running, the generator B can be used for the aircraft instrumentation. • Generator A 14.2 V/16 A (220 W nominal capacity at 20 °C/68 °F) • Generator B 14.2 V/30 A (420 W nominal capacity at 20 °C/68 °F)

    ATTENTION If generator A fails, generator B takes over its functions. The airframe electrical components and the instruments will be supplied by the battery. The battery will no longer be charged!

    ATTENTION If generator B fails, the battery will no longer be charged. The engine still runs on generator A and the instruments will be supplied by the battery. The function of the instruments depends on the state of charge of the battery. The charging of the battery from generator B is not monitored by the EMS. An ammeter has to be provided by the aircraft manufacturer according to the latest requirements. 