fbpx

 

  • Re: Erratic Manifold Pressure 912ULS

    by » 2 years ago


    Michelle i notice from your pics that there seems to be very small white corrosion specks on both the aluminium tube and the sensor casing.

    I would firstly very gently push and pull the 2 wires where they go into the spade terminals. If there is ANY movement then that would be the place to start. I also noticed that the crimper used was a single compression type which only half does the job. Next if that is corrosion I can see I would remove the spades from the small screw connections and clean them up as well.

    These are easy no cost things to try before going down the replacement path.

     

    Regards........Chook.

     


    Thank you said by: Michelle Bigham

You do not have permissions to reply to this topic.