Poor Starting 912iS
Poor Starting from cold - Starts, Runs for 1 - 2 secs then Stops - takes 4-5 goes before it runs OK
Notices Gurgling Noise in Fuel System, near Fuel Pressure Regulator.
We have been running a 912iS Engine for 4 years, this is our 2nd Engine the first one did 1240 hrs before we changed it due to high maintenance and the 2nd Engine has done 500 hrs. Apart from all the other problems they have all started well, first press of the button. However, within the past few weeks the engine fires up but stops after 1-2secs, it then takes approx. 4-5 goes before it starts, once started it is Ok for the rest of the day.
Things we have done.
1. Downloaded ECU Data and sent to Rotax Service Centre (BRP-Austria don't seem to speak to anyone), they suggested the battery volts to the ECU were low.
2. Replaced Battery - higher capacity one - No difference still poor initial cold start
3. Removed and Cleaned all Connectors, Plugs, Fuses etc (Rotax still won't supply a Circuit Schematic for the Fuse Box or a Wiring Diagram)
4. Changed Fuel (Coarse & Fine) Filters
5. Noticed a gurgling noise in the fuel system with Pump(s) on - no engine running. This was coming from the Fuel Pressure Regulator.
6. Removed Fuel Pressure Regulator - inspected internal screen - all clear - re-fitted - still gurgling noise with Pumps on
7. Checked Pressure 3 Bar (43.5 psi) all OK
8. No fuel leaks
9. Spotted an Old Post with someone who got Air in the System and had similar starting problems
Has anyone else seen this ?
Regards, Malc