fbpx

 

I need to replace egt probes again ( about once a year ) is there a better probe and where to get.
  • Re: temp probes for 912ul

    by » 9 years ago


    The EGT probes should last a lot longer than a year. Are they mounted closer than 100mm (4") to the exhaust flange and getting too hot? Most last years. Is it the probe burning out or moving the wire around too much where it comes out of the probe causing a bad connection?

    Roger Lee
    LSRM-A & Rotax Instructor & Rotax IRC
    Tucson, AZ Ryan Airfield (KRYN)
    520-349-7056 Cell


  • Re: temp probes for 912ul

    by » 9 years ago


    thank you probes are definitely not 100mm out probably the problem. going out today to re drill and reset new probes. will have local shop weld old holes.